P204713

Service Bulletin Details

Public Details for: P204713

Repair instructions to address fault codes P204713 reductant injection valve control bank 1 unit 1 ⿿ circuit open


- 2020 - 2019 - 2018 - 2017 - 2016 - 2015 - 2014 - 2013 -

DTC (Code)
Codigo:
Bulletin:
P2047-13 // SPN 5394 FMI 5
RD18-002
Date Fecha: June 22, 2018
Description:
Reductant Injection Valve Control Bank 1 Unit 1 – Circuit Open
Application:
US13 – US20 Emissions
General Information
These repair instructions are intended to address the following fault(s):
DTC
P2047-13
// SPN
5394 FMI
5
Description
Reductant
Injection Valve
Control Bank 1
Unit 1 – Circuit
Open
Possible Cause
•
•
•
Connector
Wiring harness
Aftertreatment diesel exhaust fluid (DEF)
dosage valve
Possible (Observable)
Symptoms
No aftertreatment diesel
exhaust fluid (DEF)
dosage
Required Parts
Part Number
Description
Quantity
22391563
DEF Dosage Valve
1
Repair Instructions
Aftertreatment Diesel Exhaust Fluid (DEF) Dosing Valve, Replacement
Removal
1.
2.
3.
4.
Apply the parking brake and transmission in neutral.
Open rear engine service doors.
Remove rear top access panel.
Remove all cables from the ground (negative) battery terminals to prevent personal injury from electrical shock
and prevent damage to electrical components.
5. Label coolant lines to aid in reassembly.
© 2016 Information is subject to change without notice.
Page 1 of 3
DTC (Code)
Codigo:
P2047-13 // SPN 5394 FMI 5
Bulletin:
RD18-002
Date Fecha: June 22, 2018
6. Push the quick connect fitting coupling in the ON direction, squeeze the holding clip lugs on either side of the
connector and pull to disconnect the DEF supply line from the dosing valve. Cover the DEF line with a plastic
bag and secure the bag with a tie wrap to prevent spillage on nearby components. Note: If the DEF line will
remain open for an extended period of time, seal the opening to prevent crystallization of fluid in the line.
1. DEF Supply Line
2. Dosing Valve
7. Crimp off coolant lines, push the quick connect fitting coupling in the ON direction, squeeze the holding clip lugs
on either side of the connector and pull to disconnect the coolant lines from the dosing valve.
1. Coolant Lines
8. Disconnect the electrical connector and position away from the aftertreatment DEF dosing valve. Cover the
connector with a plastic bag and secure the bag with a tie wrap to protect it from the aftertreatment DEF.
1. Electrical Connector
© 2016 Information is subject to change without notice.
Page 2 of 3
DTC (Code)
Codigo:
Bulletin:
P2047-13 // SPN 5394 FMI 5
RD18-002
Date Fecha: June 22, 2018
9. Remove and discard the aftertreatment DEF dosing valve fasteners. Remove the aftertreatment DEF dosing
valve from the aftertreatment DPF. Note: If the dosing valve will be reused, use plug kit 21376772 to cap the
coolant and DEF valve fittings to prevent contamination and crystallization of DEF in the valve.
1. Fasteners
2. Dosing Valve
10. Remove and discard the aftertreatment DEF dosing valve gasket.
Installation
1. Make sure that the mounting surface on the DPF outlet pipe is clean.
2. Position a new gasket on the aftertreatment DEF dosing valve and install the valve on the aftertreatment DPF
using new fasteners. Tighten the fasteners to specification, refer to Function Group 20, Specifications.
3. Remove the protective covering and reconnect the electrical connector to the aftertreatment DEF dosing valve.
4. Verify the connector is clean and shows no signs of damage. Push the fitting onto the valve until it stops to
reconnect the coolant lines to the aftertreatment DEF dosing valve. Pull the fitting in the OFF direction to ensure
the connector is locked in place.
5. Remove the protective covering and verify the connector is clean and shows no signs of damage. Push the fitting
onto the valve until it stops to reconnect the DEF supply line to the aftertreatment DEF dosing valve. Pull the
fitting in the OFF direction to ensure the connector is locked in place.
6. Install all previously removed cables to the ground (negative) battery terminals.
7. Connect VCADS and clear any codes. Run SCR Dosing Test 1 in VCADS to fill the line and dosing valve with
DEF. Check for any DEF leaks at the connection.
8. Clean any residual fluids from the dosing valve and lines. Start the engine and check for coolant leaks at the
dosing valve. Run the DEF Tank Heating Valve Activation Test in VCADS to purge air from the coolant lines.
Ensure coolant is at the correct level after test. Clear any codes as required. Replenish the engine coolant level
as required.
9. Install rear top access panel.
10. Close rear engine service doors.
Additional Resources
These repairs are the most likely fix for the identified fault, if this does not fix the issue, Tech Tool will need to be
used for more detailed diagnostics. If filing a warranty claim, please include the ASIST case number.
Labor Code
2589-03-02-19
1.3
Causal Part
22391563
© 2016 Information is subject to change without notice.
Page 3 of 3


© dot.report 2024

Use of this information constitutes acceptance for use in an AS IS condition. There are NO warranties, implied or otherwise, with regard to this information or its use. Any use of this information is at the user's risk. It is the responsibility of user to evaluate the accuracy, completeness or usefulness of any information, opinion, advice or other content. EACH USER WILL BE SOLELY RESPONSIBLE FOR ANY consequences of his or her direct or indirect use of this web site. ALL WARRANTIES OF ANY KIND ARE EXPRESSLY DISCLAIMED. This site will NOT BE LIABLE FOR ANY DIRECT, INDIRECT or any other kind of loss.